BuildingSync XML Schema Changelog

Modified on Wed, 5 Oct, 2022 at 12:29 PM

Buildings may be exported from and imported into the Audit Template individually or in bulk to create duplicate report entries, to save data entry steps, and/or to facilitate the transfer of data to and from other software platforms using BuildingSync® XML files.  See the Importing and Exporting page for details. 


BuildingSync® XML, developed by National Renewable Energy Laboratory, is a standardized language for commercial building energy audit data that software developers may use to exchange data between audit tools. For more information on BuildingSync, visit https://buildingsync.net, which includes a data dictionary, example files, and an implementation guide (see https://buildingsync.net/documents/).  


The BuildingSync XML schema changelog displayed here may be used as a reference for developers to see what has been updated in version releases and incorporated into the Audit Template.


v2.4.0 - 31 Oct 2022


  • Supported schema versions:
    • Only "2.4.0" is allowed as value of /auc:BuildingSync/@version property.
  • Audits:
    • Replaced "Early Compliance" user-defined field with //auc:Report/auc:EarlyCompliance element.
    • Replaced "Audit Filing Status" user-defined field with //auc:Report/auc:FilingStatus element.
  • Buildings:
    • Replaced "Demising Above Grade Wall Area" user-defined field with //auc:Building/auc:TotalCommonConditionedAboveGradeWallArea element.
    • Replaced "Multi Tenant" user-defined field with //auc:Building/auc:MultiTenant element.
    • Removed "Onsite Generation Operation Average Annual Hours" user-defined field.
    • Removed "Onsite Generation Operation Average Annual Hours Is Not Applicable" user-defined field.
  • Cogeneration systems:
    • Added //auc:OnsiteStorageTransmissionGenerationSystemType[BackupGenerator="false" & CapacityUnits = "kBtu/hr"]/auc:AverageAnnualOperatingHours element.
    • Added "Average Annual Operating Hours Is Not Applicable" user-defined field.
  • Domestic hot water systems:
    • Added //auc:DomesticHotWaterSystem/auc:ModelNumber element.
    • Added "Model Number Is Not Applicable" user-defined field.
    • Added //auc:DomesticHotWaterSystem/auc:HotWaterSetpointTemperature element.
    • Added "Hot Water Setpoint Temperature Is Not Applicable" user-defined field.
  • Energy savings measures:
    • Added //auc:Measure/auc:MeasureSavingsAnalysis/auc:AnnualSavingsByFuels element.
  • Roofs:
    • Added //auc:Roof/auc:YearInstalled element.
    • Added "Year Installed Is Not Applicable" user-defined field.
  • Use types:
    • Replaced "Percentage Dwellings Occupied" user-defined field with //auc:Section/auc:SpatialUnits/auc:SpatialUnit[auc:SpatialUnitType = "Apartment units"]/auc:SpatialUnitOccupiedPercentage element.
    • Replaced "Quantity Of Dwellings" user-defined field with //auc:Section/auc:SpatialUnits/auc:SpatialUnit[auc:SpatialUnitType = "Apartment units"]/auc:NumberOfUnits element.
  • Windows:
    • Added //auc:FenestrationSystem[auc:FenestrationSystemType/auc:Window]/auc:YearInstalled element. 
    • Added "Year Installed Is Not Applicable" user-defined field.


v2.3.0

Initial commit.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article